Power Dissipation : -
Low Level Delay Time : -
High Level Delay Time : -
Input threshold current : -
Voltage - Supply : 4.5V~5.5V;3V~5.5V
Operating Temperature : -40℃~+105℃
CMTI(kV/us) : 25kV/us
Isolation Voltage(Vrms) : 5kV
Number of Channels : 1
Input Type : DC
Description : DC SO-8 Logic Output Optoisolators RoHS
Mfr. Part # : ACPL-C797-500E
Model Number : ACPL-C797-500E
Package : SO-8
| Parameter | Symbol | Value | Units | Conditions/Notes |
|---|---|---|---|---|
| Product Name | ACPL-C797 | Optically Isolated Sigma-Delta Modulator | ||
| Resolution | 16 | Bits | Digital filter output set to 16 bits | |
| Dynamic Range | 80 | dB | With appropriate digital filter | |
| Analog Input Range (Recommended) | 200 | mV | Differential inputs | |
| Analog Input Range (Full Scale) | FSR | 320 | mV | VIN = VIN+ VIN- |
| Data Rate | 10 | MHz | Typical | |
| Supply Voltage (Analog Side) | VDD1 | 4.5 - 5.5 | V | Recommended Operating Conditions |
| Supply Voltage (Digital Side) | VDD2 | 3 - 5.5 | V | Recommended Operating Conditions |
| Operating Temperature Range | TA | -40 to +105 | C | |
| Common-Mode Transient Immunity | CMR | 25 | kV/s | |
| Working Insulation Voltage | VIORM | 1414 | Vpeak | IEC/EN/DIN EN 60747-5-5 |
| Isolation Voltage (UL 1577) | VISO | 5000 | Vrms/1 min | |
| Distance Through Insulation (DTI) | 0.5 | mm | Minimum | |
| Signal-to-Noise Ratio | SNR | 78 | dB | Min. (Typ. 78 dB) |
| Offset Drift vs. Temperature | TCVOS | 3.5 | V/C | Max. |
| Gain Error | GE | 1 | % | Max. |
| Internal Reference Voltage | VREF | 320 | mV | Typ. |
| Applications | Motor phase and rail current sensing, Power inverter current and voltage sensing, Industrial process control, Data acquisition systems, General purpose current and voltage sensing, Traditional current transducer replacements | |||
|
|